Equipment Repair Directory

Yield Monitor Calibration Log

A yield monitor only counts what it was taught to count. This log records each calibration load, the scale weight, the correction factor and the date, so a drifting sensor shows up as a trend and not as a surprise at the elevator.

Why it matters

Maps drawn from a monitor that reads 4 percent high make every field look better than it was and mislead input decisions. Weighing real loads ties the monitor to a scale. Follow the operator manual for calibration steps and ask your dealer when the factor will not settle.

Step by step

  1. Calibrate when the combine is clean, the header is set and the crop is mature, and repeat when crop, moisture or ground speed changes a lot.
  2. Run each calibration load at a steady speed with a full header, and stop the pass cleanly so the monitor records the load as one file.
  3. Weigh the load on a certified scale, subtract the empty truck or cart weight, and divide net pounds by the test weight per bushel.
  4. Read the bushels the monitor shows for the same load, and divide scale bushels by monitor bushels to get the factor.
  5. Repeat with at least three loads of different sizes, and compare the factors, since a spread above about 1 percent suggests a sensor or flow problem.
  6. Enter the averaged factor only after loads agree, and record the date, crop, moisture, speed and load size in the log.
  7. Check one full load against the scale every season and after repairs, and re-run the log if the factor drifts.

Worked example

Illustrative: Corn is figured at 56 pounds per bushel. Load 1 nets 10,080 pounds, so 10,080 / 56 = 180.0 bushels on the scale, and the monitor shows 187.2. Factor is 180.0 / 187.2 = 0.9615, meaning the monitor ran 7.2 / 180 = 4.0 percent high. Load 2 nets 15,400 pounds, or 275.0 bushels, against 285.6 on the monitor, giving 0.9629. The two differ by only 0.0014, so a factor of 0.962 is used. A 12,400-bushel monitor total becomes 12,400 x 0.962 = 11,929.

Printable worksheet: yield monitor calibration log

  • Date, crop and moisture percent: ____________________
  • Load 1 net lb ______ / lb per bushel ______ = scale bushels ______
  • Load 1 monitor bushels ______ ; factor = scale / monitor: ______
  • Load 2 net lb ______ ; scale bushels ______ ; monitor ______ ; factor: ______
  • Load 3 net lb ______ ; scale bushels ______ ; monitor ______ ; factor: ______
  • Spread between highest and lowest factor: ______ ; factor entered: ______
  • Ground speed and header width during loads: ______ mph / ______ ft
  • Next scale check date and initials: ____________

Common mistakes

  • Calibrating on a single small load, which lets the scale rounding and a start-up surge dominate the factor.
  • Using the scale gross weight instead of the net, which folds the truck tare into the bushel count.
  • Skipping the moisture and test weight entries, so the monitor and the scale are not talking about the same bushel.
  • Changing the factor mid-season to force a field total to match a bin and losing the record of what was done.

Frequently asked questions

How many loads should I use?

Three or more loads of different sizes give a more dependable factor than one. If the factors disagree by more than about a percent, look for a sensor, speed or flow cause before you enter a value.

Does the factor change with crop?

Often yes, because each crop flows differently and has its own test weight and moisture basis. Keep a separate log line per crop and follow your operator manual and dealer guidance.

Is a truck scale good enough?

A certified scale gives a sound reference. Ask your elevator or state weights and measures office about scale certification in your area, and weigh both the full and empty truck on the same scale.

Official sources