Air Seeder Calibration Guide
A seeder set from a chart can miss the target by several pounds an acre, because seed size, fan speed and meter wear change the flow. A catch test measures what the meter really delivers and tells you how far to adjust.
Why it matters
Seed is one of the largest costs on the farm, and too little or too much both cost yield. Calibrating each seed lot, not each season, protects the stand. Follow the manual calibration method, and ask your dealer or extension agronomist for target seeding rates.
Step by step
- Read the manual to find the meter calibration method, the crank or test speed and the collection point for your cart.
- Compute width times travel: divide 43,560 square feet by the seeding width in feet to get the feet traveled per acre.
- Run the meter for the test fraction of an acre, such as one tenth, catching seed from every run in a clean container.
- Weigh the catch, divide by the fraction of an acre used to get pounds per acre, and compare it to your target.
- Adjust the meter by the ratio of target to measured, then repeat the test until two catches agree within about 2 percent.
- Record the final setting with seed variety, seed lot and date, and recheck after every change of seed lot or treatment.
Worked example
Illustrative: The seeding width is 40 feet, so 43,560 / 40 = 1,089 feet of travel covers one acre. A one tenth acre test catches 8.4 pounds, so 8.4 / 0.1 = 84 pounds per acre. The target is 90, so the ratio is 90 / 84 = 1.071. A meter setting of 28 becomes 28 x 1.071 = 30.0. At 16,000 seeds per pound, 90 x 16,000 / 43,560 = 33 seeds per square foot.
Printable worksheet: air seeder calibration
- Crop, variety, seed lot and treatment: ____________
- Seeding width ______ ft ; feet per acre = 43,560 / width = ______
- Test fraction of an acre ______ ; pounds caught ______ ; pounds per acre = caught / fraction: ______
- Target ______ lb per acre ; adjustment ratio = target / measured: ______
- Old meter setting ______ x ratio = new setting ______
- Seeds per pound ______ ; seeds per sq ft = lb per acre x seeds per lb / 43,560: ______
- Second catch pounds ______ ; agreement within 2 percent (yes or no): ______
Common mistakes
- Calibrating with clean untreated seed, then planting treated seed that flows differently through the same meter.
- Catching from a single run and assuming every other run delivers the same amount.
- Testing at a fan speed or crank rate different from the speed you will use in the field.
- Skipping the repeat test after the first adjustment and trusting the arithmetic alone.
Frequently asked questions
How often should I recalibrate?
Recalibrate for each new seed lot, species or treatment, and after meter repairs. Many operators also check mid-season, since vibration and wear change delivery. Your dealer can say what the manual advises.
Why does my field rate differ from the test?
Slip, seed bounce, hill slopes and fan speed all change field delivery. Compare the tank weight used with acres covered, then adjust the setting. Ask your dealer if the gap stays large.
Where do I get a target seeding rate?
Seeding rates depend on crop, soil, moisture and the goal. Ask your local extension office or a certified crop adviser for tested ranges, and check the seed tag for germination and seeds per pound.
Official sources
- eXtension: Cooperative Extension resources
- ASABE: American Society of Agricultural and Biological Engineers
- USDA Natural Resources Conservation Service
Educational only. Follow the operator manual, manufacturer service intervals, label or SDS and OSHA rules. State repair and parts directory.