A broadcast seeder drops seed by gate opening, and the label setting rarely matches your seed lot. This worksheet converts a target rate into pounds per minute, tests a one-minute catch, and corrects the gate until the numbers agree.

Why it matters

Seed size and shape change flow, so the same gate opening can deliver far different rates on two lots. Too little leaves bare patches and too much wastes seed. A short catch test before each job costs minutes. Follow the seed tag, the seeder manual and your extension seeding guide for the target rate.

Step by step

  1. Read the target seeding rate in pounds per acre from the seed tag or your extension guide, and write it on the worksheet.
  2. Measure the effective swath width in feet from a test pass or the pattern edge, not the maximum throw printed in the brochure.
  3. Choose a ground speed you can hold in the field, then compute acres per hour as width times mph times 5,280 divided by 43,560.
  4. Multiply acres per hour by the rate and divide by 60 to find the pounds per minute the seeder must deliver.
  5. Lift the machine or collect from the spinner chute for exactly one minute with the PTO or motor at working speed, and weigh the seed caught.
  6. Divide the target pounds by the caught pounds to get the correction factor, move the gate by about that percent and retest.
  7. Repeat until the catch is within about 5 percent of target, then record the final gate setting with the seed lot and date.

Worked example

Illustrative: Target rate is 20 lb per acre, swath is 30 ft and speed is 5 mph. Acres per hour are 30 x 5 x 5,280 / 43,560 = 18.2. Pounds per hour are 18.2 x 20 = 364, so the seeder must deliver 364 / 60 = 6.07 lb per minute. A one-minute catch weighs 5.4 lb. The correction is 6.07 / 5.4 = 1.12, so open the gate about 12 percent and retest. A 40 acre field then needs 40 x 20 = 800 lb of seed.

Printable worksheet: broadcast seeder calibration

  • Seed, lot number and target rate: ____________ / ______ lb per acre
  • Swath ______ ft x speed ______ mph x 5,280 / 43,560 = ______ acres per hour
  • Rate ______ x acres per hour ______ / 60 = ______ lb per minute needed
  • One-minute catch ______ lb ; correction = needed / caught: ______
  • Gate setting start ______ ; adjusted to ______ ; retest catch ______ lb
  • Field acres ______ x rate ______ = ______ lb of seed to load
  • Final setting saved with date and operator: ____________

Common mistakes

  • Using the brochure swath width instead of the width that actually gets even coverage, which shortens the real pass spacing.
  • Catching seed with the machine idling or at the wrong PTO speed, so the flow differs from field conditions.
  • Reusing last year setting for a new seed lot without a catch test, since size and moisture change flow.
  • Weighing the catch together with the bucket or tarp and forgetting to subtract its weight.

Frequently asked questions

Why does my seeder over or under seed?

Gate openings are approximations. Seed size, coatings, humidity, wear and ground speed all change flow. A catch test with your own seed and speed is the most reliable fix, and it takes only a few minutes.

Can I calibrate by area instead of by catch?

Yes. Load a known weight, seed a measured area, and divide the weight used by the acres covered. It is slower than a catch test but checks the real pattern. Use both on a new machine.

What if the pattern is uneven across the swath?

Check for worn vanes, a bent spinner or a gate that does not open equally. Set out collection pans across the pass to see the pattern, and ask the maker or dealer for adjustment steps.

Official sources