A pump can run all season and still be slowly losing output through wear, a plugged screen or a leaking suction line. This log records flow and pressure at each check, so a trend flags the problem before the crop does.
Why it matters
Output usually declines slowly, and an operator who sees the pump every day rarely notices. A baseline reading taken on a known good day gives a fair comparison. Use the pump manual for limits, lock out the power before opening anything, and ask a technician for repairs.
Step by step
- Record a baseline at startup after service: flow in gallons per minute, discharge pressure and motor or engine load.
- Repeat the same readings at the same setting every couple of weeks and plot or list them in a column.
- Calculate percent drop from baseline flow and set an action trigger, such as a drop of 10 percent, as a placeholder until the manual or dealer gives a figure.
- Inspect the suction screen, intake and strainer for debris, and listen for gravel noise, which can mean cavitation.
- Check the shaft packing or mechanical seal: packing should drip slightly while running, but a steady stream means adjust or replace.
- Grease bearings to the manual, check alignment and coupling guards, and record vibration or heat that has changed.
Worked example
Illustrative: The baseline flow is 1,000 gallons per minute and the latest test shows 880. The drop is 1,000 - 880 = 120, or 120 / 1,000 = 12 percent. One acre-inch is about 27,154 gallons. At 1,000 gpm the pump delivers 1,000 x 60 / 27,154 = 2.21 acre-inches per hour, and at 880 gpm it delivers 52,800 / 27,154 = 1.94. The loss is 0.27 acre-inch per hour, or about 26.5 acre-inches over 100 hours, so schedule an inspection.
Printable worksheet: irrigation pump maintenance log
- Pump, well or source, and date: ____________________
- Baseline flow ______ gpm ; pressure ______ psi ; reading date ______
- Flow now ______ gpm ; drop = baseline - now: ______ gpm
- Percent drop = drop / baseline x 100: ______ ; action trigger ______ percent
- Acre-inches per hour = gpm x 60 / 27,154: ______ ; loss over 100 hr: ______
- Screen and suction checked (clear or plugged): ______
- Packing drip, bearing temperature and coupling guard: ____________
Common mistakes
- Comparing readings taken at different valve or pressure settings, so the trend means nothing.
- Tightening packing until it runs dry, which burns the shaft sleeve.
- Treating gravel noise as normal and running on until the impeller wears.
- Taking a baseline on a worn pump, so the later drop looks smaller than it is.
Frequently asked questions
How accurate does my flow reading need to be?
Consistency matters more than perfection. Use the same meter, same setting and same spot each time. If you have no meter, ask your irrigation dealer or NRCS office about flow testing.
How often should I log the pump?
Every couple of weeks in season is a common rhythm, with extra checks after any repair or after a sharp pressure change. Your dealer can advise on a schedule for your pump and well.
Is a pressure drop always a pump problem?
No. Leaks, nozzle wear, valve settings, water level changes and plugged screens also lower pressure. Log them separately, check the system, and ask a technician before blaming the pump.