A dryer log records what went in, what came out and what it cost. This one captures moisture, shrink and fuel for each batch, plus the safety control tests and cleaning steps that prevent fires, so you can spot a problem before the season ends.

Why it matters

Grain dryers combine heat, dust and long run times, so cleaning and shutdown testing matter as much as fuel savings. Batch records show when efficiency slips, which often points to plugged screens or a burner problem. Follow the manual, NFPA guidance and your gas supplier. Start each season with a clean, tested machine and a log that is already open on day one. Keep the log beside the controls.

Step by step

  1. Before the season, clean fines and trash from the plenum, columns and burner area, check for nests, and have a qualified technician inspect gas lines and the burner.
  2. Test each safety control, including high-limit shutoff, flame failure, fan interlock and emergency stop, and write the pass or fail result.
  3. Compare your moisture meter with a sample tested by your elevator or lab, and record the difference so later readings can be corrected.
  4. For each batch, record wet moisture, target moisture, temperature settings, start and end times, and the fuel used.
  5. Compute dry matter, final weight and water removed from the moisture values, then compute fuel per bushel per point removed and compare it across batches.
  6. Walk the dryer on a set schedule while it runs, watching for fire, hot spots, plugged screens, odor and unusual noise, and keep an extinguisher and exit clear.
  7. Never enter a bin or column while anything can start, and follow your confined-space procedures and call trained help.

Worked example

Illustrative: A 1,000 bushel batch at 22 percent moisture weighs 56,000 lb. Dry matter is 56,000 x 0.78 = 43,680 lb. At 15 percent moisture the weight is 43,680 / 0.85 = 51,388 lb, so 56,000 - 51,388 = 4,612 lb of water leaves, about 4,612 / 8.34 = 553 gallons. Shrink is 4,612 / 56,000 = 8.2 percent. If the batch used 150 gallons of fuel over 7 points removed, fuel per bushel-point is 150 / (1,000 x 7) = 0.021 gallons. Compare each later batch against these figures to spot a plugged screen.

Printable worksheet: grain dryer operation and maintenance log

  • Dryer, crop, batch number and date: ____________________
  • Wet moisture ______ percent ; target ______ percent ; points removed ______
  • Wet weight ______ lb ; dry matter = wet x (1 - wet moisture): ______ lb
  • Final weight = dry matter / (1 - target) = ______ lb ; water removed = wet - final: ______ lb
  • Fuel used ______ ; fuel per bushel-point = fuel / (bushels x points): ______
  • Safety controls tested (pass or fail) and date: ____________
  • Cleaning done and fire walk-through times: ____________

Common mistakes

  • Letting fines build around the burner and plenum between batches, which gives a fire fuel next to an ignition source.
  • Trusting one moisture meter reading without a lab or elevator check, so you dry to the wrong point.
  • Bypassing a high-limit or flame failure control to keep running, which removes the protection meant to stop a fire.
  • Comparing fuel use across batches without recording points removed, so a wet crop looks like a bad dryer.

Frequently asked questions

What shrink factor should I use?

The dry matter formula in the example gives the water shrink directly. Elevators often add handling shrink, so ask yours how it prices drying and shrink, and keep your own record.

How often should I clean the dryer?

Clean at the start of the season and at intervals the manual or your insurer sets, more often when the crop is dusty. Never clean while the dryer is hot or running.

Can I dry above the recommended temperature?

Higher heat risks fire, damaged grain and stress cracks. Follow the manual temperatures for each crop and use, and ask your extension specialist about limits for seed or food grade grain.

Official sources